Tesi etd-12232022-151614 |
Link copiato negli appunti
Tipo di tesi
Tesi di laurea magistrale
Autore
CAVALLI, FABIO
URN
etd-12232022-151614
Titolo
Ottimizzazione di un metodo per l'analisi di POPs a livello di ultratracce da matrici acquose polari
Dipartimento
CHIMICA E CHIMICA INDUSTRIALE
Corso di studi
CHIMICA
Relatori
relatore Prof.ssa Giannarelli, Stefania
Parole chiave
- Antarctica
- Antartide
- Arctic
- Artide
- campioni acquosi
- CB
- estrazione
- extraction
- GC-MS/MS
- IPA
- MEPS
- method optimization
- Ny-Ålesund
- ottimizzazione metodo
- PAH
- PCB
- PCN
- POPs
- Svalbard
- ultratracce
- ultratrace level
- water samples
Data inizio appello
26/01/2023
Consultabilità
Non consultabile
Data di rilascio
26/01/2026
Riassunto
Il lavoro riguarda l’ottimizzazione di un metodo d'analisi per la determinazione di inquinanti organici persistenti, presenti, in ultratracce, in matrici acquose polari. Sono stati determinati 130 composti, facenti parte di quattro classi di inquinanti di particolare interesse ambientale (clorobenzeni, policlorobifenili, policloronaftaleni ed idrocarburi policiclici aromatici). L’ottimizzazione dell’analisi concerne sia la parte strumentale, volta allo sviluppo di un metodo MRM, in modo da sfruttare al massimo le potenzialità della strumentazione GC-MS/MS a disposizione, sia la fase di estrazione del campione, condotta per mezzo della tecnica MEPS. Lo scopo di questa seconda parte è quello di minimizzare la quantità di campione necessario all’analisi ed avere a disposizione una procedura robusta e sicura per l’operatore. L’applicabilità del metodo è stata infine verificata attraverso l’analisi di campioni reali, provenienti sia dall’Artide che dall’Antartide, ed i risultati sono stati criticamente discussi in funzione delle informazioni disponibili in letteratura.
The work is about the optimization of an analytical method for the determination of persistent organic pollutants at ultratrace levels in polar aqueous matrices. One hundred and thirty compounds have been determined, belonging to three environment pollutants classes (chlorobenzenes, polychlorobiphenyls, polychloronaphthalenes, polycyclic aromatic hydrocarbons). The analysis optimization was about the instrumental part, and the extraction part. The first one is aimed at developing an MRM method and take the most advantage of the available GC-MS/MS instrumentation. The extraction part was carried out using the MEPS technique for reducing the sampling volume and a safe and rugged procedure was optimized. In order to verify the method applicability, real arctic and antarctic samples have been analyzed. The results have been finally discussed and compared with the ones available in literature.
The work is about the optimization of an analytical method for the determination of persistent organic pollutants at ultratrace levels in polar aqueous matrices. One hundred and thirty compounds have been determined, belonging to three environment pollutants classes (chlorobenzenes, polychlorobiphenyls, polychloronaphthalenes, polycyclic aromatic hydrocarbons). The analysis optimization was about the instrumental part, and the extraction part. The first one is aimed at developing an MRM method and take the most advantage of the available GC-MS/MS instrumentation. The extraction part was carried out using the MEPS technique for reducing the sampling volume and a safe and rugged procedure was optimized. In order to verify the method applicability, real arctic and antarctic samples have been analyzed. The results have been finally discussed and compared with the ones available in literature.
File
Nome file | Dimensione |
---|---|
La tesi non è consultabile. |