Riassunto
La tesi in oggetto tratta dell’efficientamento energetico di un impianto produttivo di tubi in polietilene, alimentato quasi totalmente da energia elettrica. Attualmente l’impianto presenta 4 chiller che si occupano di raffreddare l’acqua proveniente dalle 8 linee produttive, nelle quali è spruzzata sulla tubazione passante in apposite vasche di raffreddamento, per abbassarne la temperatura e portare il prodotto in uscita a temperature che non ne permettano la deformazione (prossime alla temperatura ambiente). Sono state valutate l’installazione di un sistema fotovoltaico atto a mitigare i consumi elettrici aziendali e l’integrazione di sistemi di Free Cooling in serie ai chiller oppure a supporto delle suddette vasche di raffreddamento, alleggerendo il consumo elettrico dei chiller. Infine, sarà valutata una modifica impiantistica tramite l’inserimento di due collettori dell’acqua calda e fredda assieme ad una serie di scambiatori a piastre ed ai suddetti sistemi di free cooling (“impianto ideale”).
The thesis in question deals with the energy efficiency of a polyethylene pipe production plant, powered almost entirely by electricity. Currently the plant has 4 chillers which are responsible for cooling the water coming from the 8 production lines, in which it is sprayed on the pipe passing into special cooling tanks, to lower the temperature and bring the output product to temperatures that do not allow it to the deformation (close to room temperature). The installation of a photovoltaic system aimed at mitigating the company's electricity consumption and the integration of Free Cooling systems in series with the chillers or in support of the line’s cooling tanks, reducing the electricity consumption of the chillers, were evaluated. Finally, a system modification will be evaluated through the insertion of two hot and cold water manifolds together with a series of plate exchangers and the free cooling systems ("ideal system").
The thesis in question deals with the energy efficiency of a polyethylene pipe production plant, powered almost entirely by electricity. Currently the plant has 4 chillers which are responsible for cooling the water coming from the 8 production lines, in which it is sprayed on the pipe passing into special cooling tanks, to lower the temperature and bring the output product to temperatures that do not allow it to the deformation (close to room temperature). The installation of a photovoltaic system aimed at mitigating the company's electricity consumption and the integration of Free Cooling systems in series with the chillers or in support of the line’s cooling tanks, reducing the electricity consumption of the chillers, were evaluated. Finally, a system modification will be evaluated through the insertion of two hot and cold water manifolds together with a series of plate exchangers and the free cooling systems ("ideal system").