Tesi etd-07042022-132420 |
Link copiato negli appunti
Tipo di tesi
Tesi di laurea magistrale
Autore
BELLOMO, ALESSANDRO
URN
etd-07042022-132420
Titolo
Review and thermal-hydraulic analysis of the Water Loop test facility for the ITER WCLL Test Blanket System
Dipartimento
INGEGNERIA CIVILE E INDUSTRIALE
Corso di studi
INGEGNERIA NUCLEARE
Relatori
relatore Prof. Forgione, Nicola
tutor Ing. Galleni, Francesco
tutor Ing. Arena, Pietro
tutor Ing. Galleni, Francesco
tutor Ing. Arena, Pietro
Parole chiave
- ITER
- Relap5
- Water Loop
Data inizio appello
18/07/2022
Consultabilità
Non consultabile
Data di rilascio
18/07/2092
Riassunto
The thesis work is organized in three main parts: the comparison between the CAD 3D models of the ITER WCLL Water Cooling System;
the creation of the nodalization of the Water Loop to perform the steady-state calculation with the use of Relap5/Mod3.3 code.
The Loss of Flow Accident transient analysis, also performed with Relap5/Mod3.3 code.
The aim of the comparison between the CAD 3D models is to highlight the main geometrical and layout differences between
the Water Cooling System e the Water Loop facility.
The parameters chosen to put in comparison are: the pipe length, the number of 90deg bends, the pipe diameters,
the number and relative position of the valves. All these data are collected in tables and in the so- called radar charts, to give a synoptic view of the differences that turn out from the comparison.
In the second part of the work a nodalization of the Water Loop is created to perform a steady-state calculation
with the use of Relap5/mod3.3 Sys-TH code and to carry out a comparison with the design TH parameters.
In the last part of the thesis it is performed a transient analysis, with the use of Relap5 code,
supposing a Loss of Flow Accident with the aim of study the temperature time trend in the ciruit during the postulated accident
scenario.
the creation of the nodalization of the Water Loop to perform the steady-state calculation with the use of Relap5/Mod3.3 code.
The Loss of Flow Accident transient analysis, also performed with Relap5/Mod3.3 code.
The aim of the comparison between the CAD 3D models is to highlight the main geometrical and layout differences between
the Water Cooling System e the Water Loop facility.
The parameters chosen to put in comparison are: the pipe length, the number of 90deg bends, the pipe diameters,
the number and relative position of the valves. All these data are collected in tables and in the so- called radar charts, to give a synoptic view of the differences that turn out from the comparison.
In the second part of the work a nodalization of the Water Loop is created to perform a steady-state calculation
with the use of Relap5/mod3.3 Sys-TH code and to carry out a comparison with the design TH parameters.
In the last part of the thesis it is performed a transient analysis, with the use of Relap5 code,
supposing a Loss of Flow Accident with the aim of study the temperature time trend in the ciruit during the postulated accident
scenario.
File
Nome file | Dimensione |
---|---|
La tesi non è consultabile. |