Modelling of a Coil Steam Generator for Concentrated Solar Power Applications
Dipartimento
INGEGNERIA DELL'ENERGIA, DEI SISTEMI, DEL TERRITORIO E DELLE COSTRUZIONI
Corso di studi
INGEGNERIA ENERGETICA
Relatori
relatore Franco, Alessandro
relatore Condra, Thomas J.
relatore Sorensen, Kim
relatore Condra, Thomas J.
relatore Sorensen, Kim
Parole chiave
- CSP
- effective life time
- evaporator
- solar energy
- start-up
Data inizio appello
18/07/2014
Consultabilità
Completa
Riassunto
The project investigates a new design for a CSP plant steam generation system, the Coil Steam Generator(CSG). This system allows faster start-ups and therefore higher daily energy production from the Sun. An analytical thermodynamic simulation model of the evaporator and a mechanical analysis are developed to
optimize the behavior of the system in different start-up scenarios. The results improve the effective life time (ELT) of the CSG, the thermal
flexibility of the overall CSP plant to have faster start-ups. Sensitivity analysis carried out to understand the importance of start-up time, oil circuit pressure in the CSP plant and
header thickness, show that the these variables are important to determine the total state of stress in the headers, and therefore their effective life time. Applying the results of the optimization analysis means that, the oil headers are not critical anymore regarding the start-up process and can easily resist faster start-ups.
optimize the behavior of the system in different start-up scenarios. The results improve the effective life time (ELT) of the CSG, the thermal
flexibility of the overall CSP plant to have faster start-ups. Sensitivity analysis carried out to understand the importance of start-up time, oil circuit pressure in the CSP plant and
header thickness, show that the these variables are important to determine the total state of stress in the headers, and therefore their effective life time. Applying the results of the optimization analysis means that, the oil headers are not critical anymore regarding the start-up process and can easily resist faster start-ups.