Thesis etd-10202023-182242 |
Link copiato negli appunti
Thesis type
Tesi di specializzazione (5 anni)
Author
FILONI, GABRIELE
URN
etd-10202023-182242
Thesis title
Ripristino dell'offset acetabolare anatomico nei pazienti sottoposti ad artroplastica totale di anca: confronto tra impianti tradizionali ed in assistenza robotica con dispositivo Stryker MAKO
Department
RICERCA TRASLAZIONALE E DELLE NUOVE TECNOLOGIE IN MEDICINA E CHIRURGIA
Course of study
ORTOPEDIA E TRAUMATOLOGIA
Supervisors
relatore Prof. Parchi, Paolo Domenico
relatore Dott. Calvosa, Giuseppe
relatore Dott. Calvosa, Giuseppe
Keywords
- anca
- artroplastica
- artroprotesi
- hip
- MAKO
- prosthesis
- protesi
- PTA
- robot
- robotic assistance
- Stryker
- tha
Graduation session start date
07/11/2023
Availability
Withheld
Release date
07/11/2093
Summary
L'obiettivo di questo studio consiste nella valutazione del ripristino dell'offset acetabolare anatomico in una serie di pazienti sottoposti ad intervento di artroplastica totale d'anca, suddivisi in due gruppi: i primi attraverso intervento effettuato con la metodica tradizionale ed i secondi tramite assistenza robotica con dispositivo Stryker MAKO. E' un analisi retrospettiva che valuta il risultato di operatori con esperienza decennale nella protesica d'anca tradizionale, sovrapponibile come qualità e risultato, che negli ultimi anni hanno intrapreso l'utilizzo dell'assistenza robotica MAKO.
The purpose of this study is to evaluate the restoration of anatomical acetabular offset in a series of patients undergoing total hip arthroplasty, divided into two groups: the first group receiving surgical treatment with traditional technique, and the second group with robotic assistance using the Stryker MAKO device. This is a retrospective analysis that assesses the outcomes of surgeons with over a decade of experience in traditional hip prosthetics, comparable in terms of quality and results, who have adopted the use of MAKO robotic assistance in recent years.
The purpose of this study is to evaluate the restoration of anatomical acetabular offset in a series of patients undergoing total hip arthroplasty, divided into two groups: the first group receiving surgical treatment with traditional technique, and the second group with robotic assistance using the Stryker MAKO device. This is a retrospective analysis that assesses the outcomes of surgeons with over a decade of experience in traditional hip prosthetics, comparable in terms of quality and results, who have adopted the use of MAKO robotic assistance in recent years.
File
Nome file | Dimensione |
---|---|
Thesis not available for consultation. |